A humidity indicator and a data logger answer a different question. The indicator shows whether a limit value has been exceeded. The data logger records how values have developed over time.
Humidity indicator: a visual signal
A humidity indicator card has colour spots that change colour at certain relative humidities. According to the definition in the J-STD-033 standard, the card changes from blue to pink when the indicated relative humidity is exceeded. DDC's cards change from brown to azure blue.
The card gives no time and no complete progression. It says something about the condition at the card at the moment of reading. An indicator does not absorb moisture itself and is therefore not a desiccant.
Data logger: recording over time
A data logger stores measured values, for example temperature or humidity, at a set interval. This lets you see afterwards when a change occurred and how long it lasted. You read out DDC's single-use GKLog models via USB after use and they automatically produce a PDF report. They therefore do not measure in real time.
Which do you choose?
- Do you want to know when opening a package whether a limit has been exceeded? Then an indicator fits.
- Do you want to know what happened during a journey or storage period? Then a data logger fits.
- Do you want both? Then they can complement each other.
What the outcome does and does not say
A reading or series of measurements says something about the condition at the location of the measuring device. Whether your product is in order also depends on other factors. Therefore assess the outcome within your own quality process. DDC supplies the tools and advice, not its own testing or validation service.