Oxygen absorption

Less oxygen.
Preserving
quality.

Protect what makes your product special. We help you match oxygen absorber, packaging and processing, with practical advice for your application.

Understanding the cause

A closed package
is not yet low in oxygen.

Even after closing, oxygen can be present in a package. In the free space, between the products or in the product itself. During storage, oxygen can also enter through packaging material and closures.

An oxygen absorber binds oxygen inside the package. How it works depends on the chosen version, the packaging and the conditions. That is why we start with your product and what you want to preserve.

01

Taste & smell

Oxidation can attack fats and oils and cause a rancid taste or smell.

02

Colour & composition

Oxygen can affect sensitive colourings, aromas and ingredients.

03

Preservation during storage

Look at the desired quality throughout the entire storage period, in the final packaging.

Your application

What do you want to
help preserve?

The sensitivity of the product determines what we look at. Below you will see three situations in which oxygen can play a role.

Illustrative image of packaged almonds and walnuts at a tidy packaging workstation
For fat-rich, dry products

Attention for taste
and natural oils.

In nuts and seeds, oxidation can lead to rancidity. A suitable oxygen absorber can help reduce the oxygen load, in combination with a well-sealed barrier package.

  • Choose a version that works at the water activity of your product.
  • Also include the air between nuts and seeds in the assessment.
  • Check taste and smell throughout the desired storage time.

Is your application not listed? Tell us what you pack. For other oxygen-sensitive products as well, we look at which version and product information match your question.

Suitable oxygen absorbers

A small sachet.
A focused choice.

The right version follows from your product and packaging. We help you assess the difference in activation, capacity and size.

Oxygen control

Oxygen absorbers

Take up oxygen inside a suitable, closed package.

AbsorbersProduct information

Unsure about the version?

Capacity in ml O₂ describes the amount of oxygen that can be absorbed. The DDC team helps you choose.

Ask for advice ↗
Help with your choice

The right capacity starts with the right data.

The volume on the packaging alone says too little. These four topics give direction to the choice of absorber and the checking of the application.

01THE PRODUCTProduct & water activity

What do you want to preserve? Share composition and water activity (aw): a measure of the available water in a product. That value helps to choose the activation principle.

02THE PACKAGINGPackaging & oxygen

How much free space and enclosed air is there? What oxygen barrier does the material offer? Also include seal seams and closures.

03THE CONDITIONSTime & conditions

How fast must oxygen be absorbed and how long do you want to protect? State at which temperature the product is packed, stored and transported.

04THE PROCESSINGProcessing & assessment

How do you add the sachet? How long does it remain exposed to air? Determine beforehand how you will assess residual oxygen and product quality.

100 ml O₂ is not a 100 ml package. The capacity concerns oxygen, not the total air or package volume. Look at oxygen that is present at closing, released from the product and entering later. You assess the right capacity and absorption rate under the conditions of your application.

Let us think along
01

Short exposure

Open the stock packaging only at the time of use and follow the permitted processing time for the chosen version.

02

Close carefully

Add the intact sachet before closing. Keep it out of the seal seam and follow the placement instructions.

03

Check in a targeted way

Assess residual oxygen, package integrity and product quality at pre-selected moments.

Processing & control

Assess how it works.
In your own packaging.

A well-chosen absorber works together with the packaging. Therefore check the whole: material, closure, sachet and product, under the conditions in which you actually store and transport.

Residual oxygen requires a suitable oxygen measurement. Also define with your quality manager how you assess taste, colour and microbiological safety. A low oxygen level alone does not substantiate shelf life.

Discuss your application question

DDC helps with product information and practical advice. You organise the testing and validation within your own quality process.

How we help you

Together we make
your question concrete.

You know your product and your process. We think along from our knowledge of active packaging materials. You can also contact us if you are still exploring.

01

You tell us what is going on.

Show what you pack, which change you want to limit and how the product is stored. We listen and ask targeted questions.

02

We discuss the possibilities.

We look at activation, capacity, size and processing. And we indicate which data are still needed to substantiate the choice.

03

You test the chosen approach.

You assess the combination in your own process. We help with the available specifications and processing instructions for the chosen version.

Product information

A choice you
can substantiate.

We help you obtain the available information for the chosen version. This lets you assess the properties and use within your own quality process.

Request product information
Product specifications
Type, size and activation, supplemented with available information about product or food contact for your application.
Capacity data
Absorption capacity in ml O₂ and available data on the absorption rate and relevant conditions of use.
Processing instructions
Instructions for exposure to air, placement, closing and storing unused sachets.
ATCO product overviewSizes and capacities · PDF
Open the overview

This general overview does not replace the instructions for the chosen version. Request the current product-specific information; activation differs per type.

Frequently asked questions

Good to know in advance.

What is the difference from a desiccant?→
An oxygen absorber is intended to bind oxygen. A desiccant such as silica gel absorbs water vapour. Those are different functions. If your product needs both, discuss the combination: lowering the humidity can affect the activation of certain oxygen absorbers.
How much oxygen absorber do I need?→
Look at the oxygen present at closing, oxygen from the product and the amount that enters through the packaging during storage. Activation, absorption rate and storage time also count. Share your packaging data for a targeted conversation about the choice.
Can an absorber be used together with gas packaging?→
It can, if the combination suits your product. Gas packaging lowers the initial amount of oxygen; a suitable absorber can take up remaining and later-entering oxygen. Assess the residual oxygen after gas packaging and check the result in the final packaging.
Does it work in every closed bag or jar?→
No. A package must offer sufficient resistance to oxygen transmission and be properly closed. The activation principle must also suit the contents. After opening, new air enters; therefore assess use after opening separately.
Does oxygen absorption automatically extend a product's shelf life?→
It can help limit quality loss caused by oxygen, but it does not give a fixed extension of shelf life. Recipe, process hygiene, water activity, temperature and packaging remain decisive. Have the shelf life and microbiological safety of the complete product assessed within your quality process.
How do I store unused sachets?→
Follow the instructions of the specific version. Open the stock packaging only when you need the sachets, limit exposure to air and close the remaining stock as prescribed. Do not use the sachets if the permitted exposure or storage conditions can no longer be substantiated.
Can you validate our packaging?→
DDC supplies products, information and advice; we do not offer our own validation service. You organise the testing and assessment within your own quality process or with an expert party. We are happy to think along about the product data you need for that.

View all solutions